Page 749 - Plastic Process Equipment, Inc
P. 749

RMT15 Hot Runner Control


                 INTELLIGENT SERIES • DUAL ZONE CONTROLS • LOW COST



                                           • Accepts Type J thermocouple input.  • Open thermocouple break protection with
                                                                                  jumper-selectable shutdown or average
                    2 RMB's                • Bumpless auto/manual transfer.       power output based on operation.
                       in                              ®
                   1 Unit!                 • CompuStep  bakeout feature prevents  • Preset Alarms at 30°F (17°C).
                                             moisture at startup.
                                                                                • SafeChange™ "Hot Swap" feature allows
                                           • Built-in loop break, short, open, and  safe removal and replacement of module.
                                             reverse thermocouple protection.
                                                                                • CE-compliant.


                                           PPE's RMT Series module is a microprocessor-based, dual zone temperature controller
                                           specifically designed for runnerless molding applications. It features an easy-to-use operator
                                           keypad, four LED displays, and six discrete indicators for heat output, alarm, degree F/C
                                           indication, manual and closed loop mode. RMT modules are available in 15 amp version.

                                           RMT modules provide fully self-tuning, line voltage compensating, automatic closed-loop
                                           temperature control over a wide range of operating conditions.  A single chip microprocessor
                                           performs all the proportional, integral and derivative (PID) control functions required to maintain
                                           setpoint temperature.  No operator calculations or presetting of values is needed.


                                           PERFORMANCE SPECIFICATIONS            INPUT SPECIFICATIONS
                                                                   ®
                                           Auto Control Mode  CompuCycle  system  Thermocouple (TC)  Type "J" grounded or ungrounded
                                                                                 Sensor           (jumper-selectable)
                                           Control Accuracy  ±0.1°F (±0.1°C) dependent on the
                                                           total thermal system  External (TC)   Maximum 100 ohms for rated
                                                                                 Resistance      accuracy
                                           Temperature Range  100°F to 650°F, (37°C to 343°C)
                                                                                 TC Isolation    Isolated from ground and supply
                                           Temperature Stability  ±0.5% of full scale over the ambient
                                                           range of 32 to 131°F (0 to 55°C)      voltages
                                                                                 Cold Junction   Automatic, better than 0.02°F/°F
                                           Calibration Accuracy  Better than 0.2% of full scale
                                                                                 Compensation    (0.01°C/°C)
                                           Power Response Time  Better than 0.3 seconds
                                                                                 Input Impedance  10 Megohms
                                           °F/°C           Jumper-selectable
                                                                                 Input Protection  Diode clamp, RC filter
                                                   ®
                                           CompuStep System  Variable stepping voltage, phase  Input Amplifier Stability Better than 0.05°F/°F (0.03°C/
                                           Control Mode    angle fired
                                                                                 °C)
                                                   ®
                                           CompuStep System  Approximately 5 minutes
                                           Duration                              Power Supply    Greater than 70 dB
                                                                                 Rejection Ratio
                                           CompuStep System  Steps approximately from 25 V
                                                   ®
                                           Output Voltage  RMS with 240 VAC line output,  CONTROLS AND INDICATORS
                                                           phase fired           Setpoint Control  Two buttons up or down.
                                           CompuStep  System  200°F (93°C)                       Resolution: 1°F (1°C)
                                                   ®
                                           Override Temperature                  % Power Control  Two buttons up or down.
                                           Operational Mode  a) TC open, TC reverse, Shut-  Mode Control  Push button switch with LED
                                           Priority          down and Open heater over-          indicator for manual mode and
                                                             ride CompuStep  System              closed loop
                                                                       ®
                                                           b) Manual mode overrides TC  Display Top (QTY-2)  3-digit filtered LED (red)
                                                             open, TC reverse    Display Bottom (QTY-2) 3-digit filtered LED (green)
                                           OUTPUT SPECIFICATIONS                 Status Indicators  Heat-current output
                                                                                                 Alarm
                                           Voltages        240 VAC nominal, single phase,        °F/°C
             MODEL RMT15                                   120 VAC available                     % output
                                           Power Capability  15 Amps, 3600 watts @ 240 VAC,      CompuStep ®
        15 AMP 1-11..........$415.00                       (Total both channels)                 Closed Loop
                                                                                                 Manual
                      12+ ..........$395.00  Overload Protection  Triac and load use high speed  Power ON/OFF  Rocker switch, UL, CSA, VDE
                                                           fuses. Both sides are fused (GBB).
          (Requires "MFT" Mainframes)      Power Line Isolation  Optically and transformer isolated  approved
                                                           from AC lines. Isolation voltage is  ELECTRICAL POWER SPECIFICATION
                                                           greater than 2500 volts.
                                                                                 Input Voltage   240/120 VAC, ±10% - 20%
                                           Output Drive    Internal solid state triac, triggered
            With SafeChange™                               by ac zero crossing pulses.  Frequency  50 Hz ±3 Hz, 60 Hz ±3 Hz
          Hot Swap Feature!                                                      DC Power Supplies  Internal generated, regulated and
                                                                                                 temperature compensated
                                                                                 Module Power Usage  Less than 3 watts, excluding load
                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
                                                                                                                 749