Page 748 - Plastic Process Equipment, Inc
P. 748

RMX15 Hot Runner Controls


                 INTELLIGENT SERIES • TOUCHSCREEN CONTROL

            • Modbus Communications Standard.  • Auto-tuning, with adjustable proportional  • Accepts Type J or Type K thermo-couple
                                                 band and rate.                     input (Type K requires special mainframe
            • SafeChange™ "hot swap" feature allows                                 & cables).
              safe removal and replacement of module.  • Bumpless auto/manual transfer.
                                                                                  • Built-in loop break, short, open, and reverse
                                                         ®
            • Compatible with "G" sized mainframes.  • CompuStep  bakeout feature prevents  thermocouple protection.
              Including Athena "G+" and DME "G" &  moisture at startup.
              "Smart" Series.                                                     •   Ground-fault protection.
                                               • Current monitor feature displays average
                                                 current to load.                 •   CE-compliant.
             TOUCHSCREEN                   PPE's RMX Series Touchscreen Hot Runner Control is a microprocessor-based, single zone
                                           temperature controller specifically designed for runnerless molding applications. It features an
                CONTROL                    easy to use touchscreen display that simultaneously shows process and set point values, °F
                                                                                                               ®
                                           or °C, percent output, current output, alarm, manual/closed loop mode and CompuStep . The
                                           menu system allows for simple adjustments to all parameters with just a few soft button pushes.
                                           Units have built-in diagnostics and are fully self-tuning. RMX modules are compatible with
                                           communication mainframes.
                                           RMB modules provide fully self-tuning, line voltage compensating, automatic closed-loop
                                           temperature control over a wide range of operating conditions.  A single chip microprocessor
                                           performs all the proportional, integral and derivative (PID) control functions required to maintain
                                           setpoint temperature, through an advanced auto-tune process.  No operator calculations or
                                           presetting of values is needed.
                                           For information on the CompuStep , CompuCycle , Manual Control and Safety & Diagnostics see
                                                                                 ®
                                                                     ®
                                           IMP Controller.
                                           PERFORMANCE SPECIFICATIONS            INPUT SPECIFICATIONS
                                                                   ®
                                           Auto Control Mode  CompuCycle  system  Thermocouple (TC)  Type "J" or type "K", grounded or
                                                                                 Sensor          ungrounded (menu-selectable)
                                           Control Accuracy  ±0.1°F (±0.1°C) dependent on the
                                                            total thermal system  External (TC)  Maximum 100 ohms for rated
                                                                                 Resistance      accuracy
                                           Temperature Range  32°F to 999°F, (0°C to 537°C)
                                                                                 TC Isolation    Isolated from ground and supply
                                           Temperature Stability  ±0.5% of full scale over the ambient  voltages
                                                            range of 32 to 131°F (0 to 55°C)
                                                                                 Cold Junction   Automatic, better than 0.02°F/°F
                                           Calibration Accuracy  Better than 0.2% of full scale
                                                                                 Compensation    (0.01°C/°C)
                                           Power Response Time  Better than 0.2 seconds
                                                                                 Input Impedance  10 Megohms
                                           °F/°C            Menu-selectable
                                                                                 Input Protection  Diode clamp, RC filter
                                                   ®
                                           CompuStep System  Variable stepping voltage, phase  Input Amplifier Stability Better than 0.05°F/°F
                                           Control Mode     fired
                                                                                                 (0.03°C/°C)
                                           CompuStep System  Approximately 5 minutes  Power Supply  Greater than 70 dB
                                                   ®
                                           Duration
                                                                                 Rejection Ratio
                                           CompuStep System  Steps approximately from 25 V
                                                   ®
                                           Output Voltage   RMS with 240 VAC line output,  CONTROLS AND INDICATORS
                                                            phase fired          Setpoint Control  Two soft buttons up or down.
                                                   ®
                                           CompuStep  System  200°F (93°C)                       Resolution: 1°F (1°C)
                                           Override Temperature                  % Power Control  Two soft buttons up or down.
                                           Operational Mode  a) TC open, TC reverse, Shut-  Mode Control  Menu-selectable
                                           Priority          down and Open heater over-
                                                                       ®
                                                             ride CompuStep  System  Display     Color LCD
                                                            b) Manual mode overrides TC  Status Displayed  Process Value (PV)
                                                             open, TC reverse                    Setpoint (SP)
                                                                                                 Heat-current output
                                           OUTPUT SPECIFICATIONS                                 Alarm
                                           Voltages         240 VAC nominal, single phase,       °F/°C
                                                            120 VAC available                    % output
                                                                                                 CompuStep ®
                                           Power Capability  15 Amps, 3600 watts @ 240 VAC       Normal, Manual, Standby
                                           Overload Protection  Triac and load use high speed  Power ON/OFF  Rocker switch, UL, CSA, VDE
              MODEL RMX15                                   fuses. Both sides are fused .        approved
        15 AMP 1-11..........$350.00       Power Line Isolation  Optically and transformer isolated  ELECTRICAL POWER SPECIFICATION
                                                            from AC lines. Isolation voltage is
                      12+ ..........$340.00                 greater than 2500 volts.  Input Voltage  240/120 VAC, ±10% - 20%
                                           Output Drive     Internal solid state triac, triggered  Frequency  50 Hz ±3 Hz, 60 Hz ±3 Hz
                                                            by ac zero crossing pulses.  DC Power Supplies  Internal generated, regulated and
         (Requires Communications Mainframes)
                                                                                                 temperature compensated
                                                                                 Module Power Usage  Less than 3 watts, excluding load
                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
        748
   743   744   745   746   747   748   749   750   751   752   753