Page 745 - Plastic Process Equipment, Inc
P. 745
RMB Non-Modular Hot Runner Controls
1 - 12 ZONES • LOW COST
6 ZONES
Part No. RMB6
$1,725.00
Accessories needed:
1 ea. - Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . #MPC8C10 (10')
or . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #MPC8C20 (20')
1 ea. - TC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #TC8C10 (10')
or . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #TC8C20 (20')
1 ea. - Terminal Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #PTC8TBM
1 ea. - Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #PIC8M
17-1/4" W x 13-1/2" D x 6" H 1 ea. - TC Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #MTC8
12 ZONES
Part No. RMB12
$2,600.00
Accessories needed:
1 ea. - Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . #MPC12C10 (10')
or . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #MPC12C20 (20')
1 ea. - TC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #TC12C10 (10')
or . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #TC12C20 (20')
1 ea. - Terminal Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #PTC12TBM
1 ea. - Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . #PIC12M
22-1/4" W x 13-1/2" D x 6" H 1 ea. - TC Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #MTC12
Part No. 64U01 - Replacement Triac Driver Board for RMB6 & RMB12 (includes triac driver board, triac and heat sink pad) . . . . . . . . . . . . . . . . . $29.00
PERFORMANCE SPECIFICATIONS INPUT SPECIFICATIONS
Auto Control Mode CompuCycle system Thermocouple (T/C) Type “J” or “K” grounded
®
Control Accuracy ± 0.1°F (± 0.1°C) dependent on the or ungrounded
total thermal system External T/C Resistance Max 100 ohms for rated accuracy
Temperature Stability ± 0.5% of full scale over the Cold Junction
ambient range Compensation Automatic, better than 0.02°F/°F (0.01°C/°C)
Calibration Accuracy Better than 0.2% of full scale Input Impedance 10 megohms
Power Response Time Better than 400 ms Input Protection Diode clamp RC filter
Process Sampling 100 ms Common Mode
°F/°C Field Configurable Rejection Ratio Greater than 100 dB
CompuStep System Power Supply
®
Control Mode Variable stepping voltage, phase fired Rejection Ratio Greater than 70 dB
Duration Approximately 5 min.
Output Voltage RMS with 240 VAC line output, phase fired
Override Temperature 200°F (93°C) CONTROLS & INDICATORS
Operation Mode Priority a: T/C open, T/C reverse, Shutdown and 8 Control Switches
open heater override CompuStep ® 6 Status LED’s per zone
b: Manual mode overrides T/C open, T/C Degrees “F” and “C” Status indicators
reverse LCD Display 2 Line x 24 Characters (RMB06)
2 Line x 24 Characters x 2 (RMB12)
2 Line x 16 Characters (RMB01-03)
OUTPUT SPECIFICATIONS
Voltages 240 VAC nominal, single
phase, 120 VAC available TECHNICAL OPERATING LIMITS
Power Capability* 15 amperes, 3600 watts @ 240 VAC per zone Input Voltage 240 VAC +10/-20%
Overload Protection Type (ABC) fuses Ambient Temperature 32 to 122°F (0 to 50°C)
Power Line Isolation Optically and transformer isolated from AC Relative Humidity 90% non-condensing
lines. Isolation voltage is greater than 2500 volts Frequency 50-60 Hz
Output Drive Internal solid state triac
* 15 amperes, 3600 watts @ 240 VAC per cabinet RMB1, RMB2 & RMB3.
®
For information on the CompuStep , CompuCycle , Manual Control and Safety & Diagnostics see IMP Controller.
®
PLASTIC PROCESS EQUIPMENT, INC. www.ppe.com
e-mail: sales@ppe.com
E 8303 CORPORATE PARK DRIVE W 6385 MONTESSOURI STREET
A MACEDONIA, OHIO 44056-2300 E LAS VEGAS, NEVADA 89113-1186 Toll Free: USA, Canada & Mexico
S 216-367-7000 • FAX: 216-367-7022 S 702-433-6385 • FAX: 702-433-6388 800-362-0706
T TOLL FREE: 800-321-0562 T TOLL FREE: 800-258-8877 Order Fax: 800-223-8305
745