Page 747 - Plastic Process Equipment, Inc
P. 747
RMB15 & RMB30 Hot Runner Controls
INTELLIGENT SERIES • LOW COST • MORE FEATURES
• Compatible with "G" sized mainframes. • Bumpless auto/manual transfer. • Ground-fault protection (U.S. model).
Including Athena "G+" and DME "G" &
®
"Smart" Series. • CompuStep bakeout feature prevents • Preset Alarms at 30°F (17°C).
moisture at startup.
• Accepts Type J or Type K thermo-couple • Jumper-selectable self-start mode.
input (Type K requires special mainframe • Current monitor feature displays average
& cables). current to load. • SafeChange™ "hot swap" feature allows safe
removal and replacement of module.
• Auto-tuning, with adjustable proportional • Built-in loop break, short, open, and reverse
band and rate. thermocouple protection. • CE-compliant.
With SafeChange™ PPE's RMB Series module is a microprocessor-based, single zone temperature controller
Hot Swap Feature! specifically designed for runnerless molding applications. It features an easy-to-use operator
keypad, two LED displays, and three discrete indicators for heater-current, alarm, and manual
mode. Units have built-in diagnostics and are fully self-tuning. RMB modules are available in
15 and 30 amp versions and are compatible with all previous "G" series mainframes.
RMB modules provide fully self-tuning, line voltage compensating, automatic closed-loop
temperature control over a wide range of operating conditions. A single chip microprocessor
performs all the proportional, integral and derivative (PID) control functions required to maintain
setpoint temperature, through an advanced auto-tune process. No operator calculations or
presetting of values is needed.
For information on the CompuStep , CompuCycle , Manual Control and Safety & Diagnostics see
®
®
IMP Controller.
PERFORMANCE SPECIFICATIONS INPUT SPECIFICATIONS
®
Auto Control Mode CompuCycle system Thermocouple (TC) Type "J" or type "K", grounded or
Sensor ungrounded (jumper-selectable)
Control Accuracy ±0.1°F (±0.1°C) dependent on the
total thermal system External (TC) Maximum 100 ohms for rated
Resistance accuracy
Temperature Range 32°F to 999°F, (0°C to 537°C)
TC Isolation Isolated from ground and supply
Temperature Stability ±0.5% of full scale over the ambient voltages
range of 32 to 131°F (0 to 55°C)
Cold Junction Automatic, better than 0.02°F/°F
Calibration Accuracy Better than 0.2% of full scale
Compensation (0.01°C/°C)
Power Response Time Better than 0.3 seconds
Input Impedance 10 Megohms
°F/°C Jumper-selectable
Input Protection Diode clamp, RC filter
CompuStep System Variable stepping voltage, phase Input Amplifier Stability Better than 0.05°F/°F (0.03°C/
®
Control Mode fired
°C)
®
CompuStep System Approximately 5 minutes Power Supply Greater than 70 dB
Duration
Rejection Ratio
CompuStep System Steps approximately from 25 V
®
Output Voltage RMS with 240 VAC line output, CONTROLS AND INDICATORS
phase fired Setpoint Control Two buttons up or down.
®
CompuStep System 200°F (93°C) Resolution: 1°F (1°C)
Override Temperature % Power Control Two buttons up or down.
Operational Mode a) TC open, TC reverse, Shut- Mode Control Push button switch with LED
Priority down and Open heater over- indicator for manual mode
®
ride CompuStep System
Display Top: 3-digit filtered LED
b) Manual mode overrides TC Bottom: 4-digit filtered LED
open, TC reverse
Status Indicators Heat-current output
OUTPUT SPECIFICATIONS Alarm
Voltages 240 VAC nominal, single phase, °F/°C
120 VAC available % output
CompuStep ®
Power Capability 15 Amps, 3600 watts @ 240 VAC, Normal, Manual, Standby
30 Amps, 7200 watts @ 240 VAC
MODEL RMB15 Overload Protection Triac and load use high speed Power ON/OFF Rocker switch, UL, CSA, VDE
fuses. Both sides are fused (GBB). approved
15 AMP 1-11..........$295.00
Power Line Isolation Optically and transformer isolated ELECTRICAL POWER SPECIFICATION
12+ ..........$285.00 from AC lines. Isolation voltage is
greater than 2500 volts. Input Voltage 240/120 VAC, ±10% - 20%
Output Drive Internal solid state triac, triggered Frequency 50 Hz ±3 Hz, 60 Hz ±3 Hz
MODEL RMB30 by ac zero crossing pulses. DC Power Supplies Internal generated, regulated and
temperature compensated
30AMP ............... $750.00 Module Power Usage Less than 3 watts, excluding load
PLASTIC PROCESS EQUIPMENT, INC. www.ppe.com
e-mail: sales@ppe.com
E 8303 CORPORATE PARK DRIVE W 6385 MONTESSOURI STREET
A MACEDONIA, OHIO 44056-2300 E LAS VEGAS, NEVADA 89113-1186 Toll Free: USA, Canada & Mexico
S 216-367-7000 • FAX: 216-367-7022 S 702-433-6385 • FAX: 702-433-6388 800-362-0706
T TOLL FREE: 800-321-0562 T TOLL FREE: 800-258-8877 Order Fax: 800-223-8305
747