Page 734 - Plastic Process Equipment, Inc
P. 734
EDGE PLUS TOUCHSCREEN
HOT RUNNER TEMPERATURE CONTROL SYSTEM
USER INTERFACE: CONSTANT MONITORING:
• Full Color High Resolution 8” (13, 24, 36 & 48 zone) or • Automatic Frequency Detection
10.1” (72 & 120 zone) Wireless Screen with Remote • AC Input Voltage Display
Mounting capability • Current Monitoring
• Remote monitoring through wifi network using included program • Resistance and Wattage Monitoring
• If the interface fails, the system will still control temperatures • Thermocouple Noise Monitoring
• Intuitive Interface with Control Panel Design • Full Report Capabilities - Alarm History,
• Fully Customizable Mold Profiles - Give each mold its own profile Temperature & Variation, and User
for easy changeouts System Change Reports
• SPC Data Logging
• Reporting Utilities and Printing FAULT DETECTION ALARMS:
• Unlimited Storage of Mold Profiling • Miswired Power Cable or Mold
• User Level Security • Miswired Thermocouple Cable or Mold
• Emergency Alternative Interface (Requires a PC running • Over/Under Temperature Alarm (adjustable)
Windows XP or Windows 7) • Thermocouple Alarms:
• Degrees C or F (User Selectable) Open, Shorted & Reversed T/C
• Auto Grouping - Intelligent automatic grouping of controllers • Heater Power Alarms:
after startup Open, Shorted & Heater Runaway
• Manual Grouping • Open Fuse Detection
• Heater Resistance & Wattage
INTELLIGENT DESIGN: • Over Current
• Full Modular Controller Cards - Hot Swappable
• Intelligent Diagnostics Mode - Power and T/C Wire Testing PROTECTION FEATURES:
• Algorithmic Compensation for Any Heater Type • Over Current Protection
(Adaptive PID Control) with High Speed Execution • High Voltage T/C Circuit Protection
• Power Output Control - Phase Angle, Zero Cross or Phase Control • Fused AC Inputs (Both Legs)
• Standard Operating Modes: Soft-Start, Manual, Auto, Standby & Boost • Output - High Speed Fuse
• Auto Slaving - Controller recieves thermocouple information from • Shutdown Mold Machine on Critical
another controller in the same group to continue without interruption. Failure Via Relay
• Bumpless Transfer - If a controller was not grouped and the • System AC Input Circuit Breaker
thermocouple fails, the controller will use the average % power it
recorded to maintain temperature. INPUT/OUTPUT:
• Autoset Maximum Heater Current - Automatically detects and sets the • Remote Standby Input - Sends controllers
maximum heater current into standby mode when activated
• Even Temperature Rise - Controlled heater temperature rise to • External Relay Output - Relay closes on
within 20°F across all zones user selectable alarms
• Emergency Start without interface (in case of interface failure as • Audible Siren Alarm
long as proper shutdown procedure is followed) • Red LED Light Alarm
15 AMP EDGE PLUS PERFORMANCE
CONTROLLER CARD* Control Accuracy: ±0.1°F (±0.05°C)
Process Sampling:
< 3ms
Power Response: < 100ms
SPECIAL
SALE INPUT SPECIFICATIONS
Thermocouple Type: Type J (Standard)
Part No. QE-15 (Grounded and Ungrounded) Type K (User Selectable)
Protection: Fused
1-11 ......... $350.00 Diode Clamp
12+ .......... $335.00 RC Filter
Operating Range: 0 - 1200°F (0 - 648°C)
$ 315 .00 ea. CMRR > 100db
ELECTRICAL
Input Voltage: 208-240VAC
Frequency: 47-63Hz (Autodetected)
* Order 1 card per zone of control required. Module Ratings: 15 Amps/zone
Use only with EMF Mainframes. 3600 Watts/zone
PLASTIC PROCESS EQUIPMENT, INC. www.ppe.com
e-mail: sales@ppe.com
E 8303 CORPORATE PARK DRIVE W 6385 MONTESSOURI STREET
A MACEDONIA, OHIO 44056-2300 E LAS VEGAS, NEVADA 89113-1186 Toll Free: USA, Canada & Mexico
S 216-367-7000 • FAX: 216-367-7022 S 702-433-6385 • FAX: 702-433-6388 800-362-0706
T TOLL FREE: 800-321-0562 T TOLL FREE: 800-258-8877 Order Fax: 800-223-8305
734