1/4 DIN TEMPERATURE CONTROL


                                 SPECIFICATIONS & PRICES


         Panel Cutout: 3.622" (92mm) sq.
                                       118.2mm                   Linear Input: Type L1 to L6 (Refer to Ordering Codes)
                      100.3mm           (4.654")
                      (3.950")  18.21mm  100mm                   Engineering Units     Scalable, -1999 to 9999
                               (0.717")  (3.937")
                                                                 Digital Filtering     0.1, 1.0, or 10 sec
                                                                 Decimal Position      Selectable, none, 1/10 or 1/100
              100.3mm                            91.44mm
              (3.950")                           (3.600")
                                                                 Control Characteristics
                                                                 Setpoint Limits  Limited to configured range of TC and RTD
                                                                 Alarms         Adjustable for high/low; selectable process
         Selectable Inputs                                                      or deviation
         Thermocouple   K, J, N, R, T, S                         Rate           0 to 900 sec
                        Maximum lead resistance, 100 ohms for    Reset          0 to 3600 sec
                        rated accuracy                           Cycle Time     0.2 to 120 sec
         RTD            Platinum, 3-wire, 100 ohms at 0°C, DIN   Gain           0 to 400
                        curve standard (0.00385)                 Gain Ratio     0 to 2.0 (in 0.1 increments)
         Linear         Current and voltage (refer to ordering note)
                                                                 Control Hysteresis 1 to 100 (on/off configuration)
                                                                 Spread (Output 2) 0 to 100 (above setpoint)
         Output Options                                          Ramp to Setpoint 1 to 100 minutes
         #1 reverse-acting                                       Autotune       Operator-initiated from front panel
         #2 direct-acting                                        Manual Control  Operator-initiated from front panel
         B             Relay 5 A @ 120 Vac  3 A @ 240 Vac
         F             4-20 mA, 500 ohms max
         S             20 Vdc pulsed                             General
         T             Solid-state relay, 120/240 Vac, zero voltage  Line Voltage    115 to 230 Vac ±10%, 50/60 Hz
                       switched, 1A continuous, 10A surge @ 25°C                     115 to 300 Vdc ±10%, (auto polarity)
         Alarms        Optically isolated Triac, rated 1 A, 120/240  Display         Dual, 4-digit, Process: orange, 0.55"
                       Vac @ 25°C DC - 20 mA sink or 24 V supply                     (14mm) Menu/parameter: green,
                                                                                     0.36" (9.2MM)
                                                                 Power Consumption   Less than 6 VA (instrument)
         Performance                                             Weight              < 15 oz (425 g)
         Accuracy              ±0.2% of FS, ± one digit          Front Panel Rating  NEMA 4X
         Setpoint Resolution   1 count/0.1 count                 Operating Temperature 32 to 131°F (0 to 55°C)
         Repeatability         ±1.0 count                        Humidity Tolerance  90% R.H. maximum, non-condensing
         Temperature Stability  5µ V/°C maximum                  Memory Protection   Solid-state, nonvolatile memory
         TC Cold End Tracing   0.05°C/°C ambient                 Connections         Input and output via barrier strip,
         Noise Rejection       Common mode > 100 dB                                  with locking terminals
                               Series mode > 70 dB               Contacts            Twin bifurcated, double-wipe
         Process Sampling      10 Hz (100 ms)
                                                                        Specifications subject to change without notice.
                                                       Output 2                 Alarm 1            Communications
                                                    Configuration Code  Price  Configuration Code  Price  Configuration Code  Price
           Input      Range   Code              0=None N/C  F=4-20 mA  $30.00  0=None     N/C     0=None        N/C
           "K" TC   0 to 2460°F  KF             B=Relay  S=Pulsed 20 Vdc    B=Relay               A=RS232
           "K" TC   -18 to 1349°C  KC           T=S.S. Relay         $25.00  T=S.S.Relay  $25.00  B=RS485      $95.00
           "J" TC   0 to 1400°F  JF
           "J" TC   -18 to 760°C  JC
           "N" TC   0 to 2370°F  NF
           "N" TC   -18 to 1299°C  NC             25-
           "R" TC   0 to 3200°F  RF
           "R" TC   -18 to 1760°C  RC                                                    Option 1
           "T" TC   -200 to 601°F  TF                                                 Configuration Code  Price
           "T" TC   -129 to 316°C  TC                                                 0=None        N/C
                                            Output 1                 Alarm 2
           "S" TC   0 to 3200°F  SF     Configuration Code  Price  Configuration Code  Price  B=Remote setpoint  $75.00
           "S" TC   -18 to 1760°C  SC  0=None  S=Pulsed 20 Vdc   0=None        N/C
         100 ohm RTD  -328 to 1562°F  PF  B=Relay  T=S.S. Relay  N/C  B=Relay
         100 ohm RTD  -200 to 850°C  PC  F=4-20 mA               T=S.S.Relay  $25.00               Option 2
         100 ohm RTD  -199.8 to 449.9°F  DF                                                    Configuration Code  Price
         100 ohm RTD  -128.8 to 232.2°C  DC                                                  0=None             N/C
           1 to 5 V  Scaleable  L1*                                                          1=Transducer excitation 10 V
          10 to 50 mV  Scaleable  L2*               BASE PRICE                               2=Transducer excitation 12V  $75.00
          4 to 20 mA  Scaleable  L3*
           0 to 5 V  Scaleable  L4*                $ 405.       00                          Replacement  Part  Price
          0 to 50 mV  Scaleable  L5*                                                          Outputs     No.
          0 to 20 mA  Scaleable  L6*                                                        B=Relay     OUTPUT-B
                                                                             U                                  $35.00
         *Both outputs must be ordered with these units.                                    F=4-20 mA   OUTPUT-F
                                                                            ®  L            S=Pulsed 20 Vdc  OUTPUT-S
                                                                                            T=S.S. Relay  OUTPUT-T
                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
                                                                                                                 771
   766   767   768   769   770   771   772   773   774   775   776