Page 776 - Plastic Process Equipment, Inc
P. 776

EAGLE SIGNAL CYCL-FLEX  TIMERS
                                                                                           ®
                                  FEATURES                            SPECIFICATIONS  (visit www.ppe.com for additional information)
                                  • 15 standard time ranges from 5 seconds to 30 hours.  Reset Time: 1/2 second at max. setting
              RESET TIMER         • Knob adjustable time ranges - progress pointer for  Voltage/Frequency:120V (+10, -15%), 50/60 Hz
                                   each.                                           240V (+10, -15%), 50/60 Hz
                  HP5             • Highly visible, calibrated dials  Burden: Motor: 2.45 VA, 120 VAC
                                   (7.85 inch circumference).               Clutch: 10.5 VA
                                  • Easily read and well-spaced calibrations.  Output Rating: 10 amps, resistive, 120 VAC
                                                                                  5 amps, resistive, 240 VAC
                                  • Red progress pointer displays remaining time interval.
                                                                      Electrical Lifetime:  Average contact life at full load is 250,000 operations.
                                  • Pilot light indicates when timer motor is energized.
                                                                      At 1 amp load, switch life increases to 5 million cycles. Inrush current should
                                  • Standard timers supplied with “power on” clutch  not exceed 10 amps.
                                   operation.
                                                                      Power On Response: 28 ms average pull-in, 17 ms average drop-out
                                  • Optional reverse action clutch will not reset on power  Temperature Range: 0° to 140°F (-18° to +60°C)
                                   failure.
                                                                      Vibration: Unaffected by 2.5G sinusoidal vibration magnitudes in both
                                  • 15 terminal ABS (UL rated 94V-0) molded housing  directions of three perpendicular mounting axes imposed from 10 to 900 Hz.
                                   has high impact resistance and will not support
                                   combustion.                        Approximate Weight: 2lb. 14oz.
                                                                                                 HP5 Schematic Diagram
                                      BASE PRICE
                                       $ 603.  00     HP5                   RECOGNIZED  CERTIFIED ®  APPROVED
                                                                                       FM
         Sym. Description  Sym. Description  Sym. Description             Sym. Description Price
          17     0-5 Sec.  2    0-150 Sec.  6    0-60 Min.                 A6   120V, 60 Hz  N/C
          15    0-10 Sec.  3     0-5 Min.  7    0-150 Min.                 B6   240V, 60 Hz  $123.00
          14    0-15 Sec.  4    0-10 Min.  8     0-5 Hr.
           0    0-30 Sec.  18   0-15 Min.  9     0-10 Hr.
           1    0-60 Sec.  5    0-30 Min.  10    0-30 Hr.
                                                                                                    ISO 9001
                                       FEATURES                   SPECIFICATIONS                     MANUFACTURED IN A
           MICROPROCESSOR              • Five time ranges from 19.999 sec. to  (visit www.ppe.com for additional information)  QUALITY SYSTEM CERTIFIED
                                                                                                         FACILITY.
                                        199 hrs.: 59 min.
             TIMER/COUNTER             • Two count rates - accept and display  Voltage/Frequency:  A6 - 120 VAC, 50/60 Hz
                                                                                B6 - 240 VAC, 50/60 Hz
                                        counts from 1 to 19999.
                 CX200                 • Two relay outputs - socket mounted  Time Inhibit/Count Line Voltage/Frequency: B6 - 240 VAC, 50/60 Hz
                                                                                                      A6 - 120 VAC, 50/60 Hz
                                        for easy replacement.     Setting Accuracy: Time: ±0.1% or 50 ms, whichever is larger Count: 100%
                                       • Two form C instantaneous contacts  Repeat Accuracy: Time: ±0.001% of setting or 35 ms, whichever is larger
                                        and two form C programmed             Count: 100%
                                        contacts.
                                                                  Repeat Time: 30 ms following voltage removal from simulated clutch input (CR1)
                                       • Programmed outputs operate in one
                                        of four load sequences; OOX, OXO,  Power on Response: 300 ms maximum after voltage applied to terminal 11
                                        OOX with pulse output, and OOX  Temperature Range: +32° to 140°F (0° to +60°C)
                                        output with repeat cycle operation.
                                                                  Output Rating: Relay: 10 amp (resistive), 120 VAC
                                       • Standard start is defined as ON delay  Mechanical Life: 20 million operations
                                        reset timer or counter.             Electrical Life: contingent upon controlled load
                                       • For standard start units, timer/counter  Vibration: Unaffected by 2.5G sinusoidal vibration magnitudes in both directions
                                        resets on power failure.  of the perpendicular mounting axes imposed from 10 to 100 Hz.
                                       • Reverse start or OFF delay units will  Battery Life: The CX uses a lithium battery with an expected life of 10 years.
                                        not reset on power failure and will
                                        continue cycle when power is
                                        restored.                                      CX200 Schematic Diagrams
                                     CX202                          ®
                BASE PRICE                                 RECOGNIZED  CERTIFIED
                 $ 657.   00                          Sym. Description Price
                                                        A6  120V, 50/60 Hz  N/C
                                                        B6  240V, 50/60 Hz  $231.00


          DIMENSIONAL                                                        MOUNTING
          INFORMATION                                                      INFORMATION
           (both models)                                                    (both models)








                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
        776