Page 113 - Plastic Process Equipment, Inc
P. 113

DEW POINT MONITOR
                    2
                 MODELS
                AVAILABLE       MEASURE THE PERFORMANCE OF

                                         YOUR DRYING SYSTEMS
                                                                                   FEATURES

          Instrument  Desiccant Test Tube  Large Digital  Audible   • -40°F to +15°F dew point range.
           Case         #DTR-30         Read-Out     Alarm
                                                                    • Electronic hygrosensor with a ± 2°F accuracy.
                                                                    • Available in a portable unit (shown) or kit form.
                                                             6'
                                                            Power   • Adjustable visible and audible alarms.
                                                            Cord
                                                                    PPE Dew Point Monitors are designed to monitor plastic drying
                                                                  systems. An electronic hygrosensor and digital processing unit
                                                                  guarantee all units maintain accuracy specifications.
                                                                    The model DPM8072 (shown) is contained in a carrying case
                                                                  for portable use. Built-in vacuum pump samples air through
                                                                  thermoplastic tubing. Capable of monitoring plastic drying systems
                                                                  up to 500°F dry bulb.

                                                                    The model DPM8073K kit (same circuitry as the DPM8072) is
                                                                  made for permanent mounting in your dryer. Just mount the circuit
                                  6' Thermoplastic
                     In-Line Air Filter  Inlet Tubing  Above Set Point (red)  board in your panel and connect the LED display and dew point
                      #3305005                                    sensor. The installation can be further customized by adding alarm
                   Version No. listed                             lights, alarm horns, or chart recorder connections.
                   inside cover door.
                                                                                     - PRICES -
                                                                   PORTABLE DEW POINT MONITOR -40°F TO +15°F
                     FUNCTIONAL DIAGRAM                            INCLUDES: Instrument Case, 6' thermoplastic sampling tube, air
                                                                   filter, desiccant test tube, & Certificate of Conformance.
                                     Humid Air
                                                                   Model DPM8072 . . . . . . . . . . . . . . . . . . . $1,475.00
                         Blower
                                                                   DEW POINT MONITOR KIT -40°F TO +15°F
                   Reactor                                         For installation in your drying equipment.
                   Air                             Hopper
                   Outlet               After                      INCLUDES: LED Display, circuit board, sensor & manifold.
                                       Heater   Dry Air            Model DPM8073K  . . . . . . . . . . . . . . . . . .$1,050.00
              Dryer
                               Right Tower
                                is Being                           REPLACEMENT DESICCANT TEST TUBE
                       Filter  Regenerated                         Part No. DTR-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  $33.00
                                                                   REPLACEMENT VACUUM PUMPS
                          Reactor                                  Part No. 3305003 - Old Style . . . . . . . . . . . . . . . . . . . .  $121.20
                          Air Inlet
                                                                   Part No. 3305004 - New Style . . . . . . . . . . . . . . . . . . .  $152.65
                                DEW POINT                          IN-LINE AIR FILTER - SEALED (tubing not included)
                                 MONITOR                           Part No. 3305005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  $19.75
                                                                   INDICATING DESICCANT MATERIAL
                         SPECIFICATIONS                            Part No. DID-01 – 1lb. Jar . . . . . . . . . . . . . . . . . . . . . . .  $23.00
                                                                   Part No. DID-05 – 5lb. Jar . . . . . . . . . . . . . . . . . . . . . .  $106.00
        Dew Point Range . . . . . . . . . . . . . . . . . . . .  -40°F to +15°F
                                                                   REPLACEMENT DEW POINT SENSOR (replace every 1-2 years).
        Dew Point Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . .  ±2°F
                                                                   Part No. 1205DM Version 2.0 . . . . . . . . . . . . . . . . . . .  $141.60
        Max Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7 psig  Part No. 1405DM Version 3.0 . . . . . . . . . . . . . . . . . . .  $159.00
        Sample Air Temperature Range . . . . . . . . . .  +0°F to 500°F  Specify version # listed inside cover door.
        Maximum Sensor Temperature . . . . . . . . . . . . . . . .  140°F  DEW POINT MONITOR “Tune-Up” (recommended once each year).
        Display Type . . . . . . . . . . . . . . . . . . . .  3-1/2 Digit LED 0.5"  Service includes: Cleaning and inspection, replacement of water vapor
        Analog Output  . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20mA  sensor, air filter, desiccant test tube and thermoplastic tubing, all
                                                                   fittings checked and vacuum/pressure tested, plus a calibration with
        Alarm Indicators . . . . . . . . . . . . .  Lamps and Audible Alarm
                                                                   a new Certificate of Conformance.
        Power Requirement . . . . . . . . . . . . . . . . . .  120VAC, 60 Hz
                                                                   “Tune-Up” for DPM8072  —  Part No. 8072CAL . . . . . . . $670.00
        Enclosure . . . . . . . . . . . . . . . . . . . . . . . . .  Instrument case
                                                                   “Tune-Up” for DPM8074  —  Part No. 8074CAL . . . . . . . $850.00
        Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12.5" x 9" x 5"  “Tune-Up” for DPM8098  —  Part No. 8098CAL . . . . . . . $670.00
        Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6.2lbs  For “Before & After” Readings add . . . . . . . . . . . . . . . . .  $190.00
                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
                                                                                                                 113