STATIC LOCATOR METER


                                 FOR LOCATING AND MEASURING
                                              STATIC CHARGES


                         FEATURES:
            •  Easy to use.
            •  20 KV at 1 inch with polarity automatically
               selected. Can measure higher values be
               increasing distance to target.
            •  Accuracy better than ±10%.
            •  Pocket-sized convenience.
            •  Size: 4-5/8" X 2-5/16" x 1-9/16" inches
            •  Weight: 8.7 oz
            •  Requires 9V battery (included).
            •  One year warranty.


          Does contamination to your product exist in a clean room
        environment?  Does a static problem still exist with your current
        filtering system? Do you have problems removing contaminants
        from plastic? If you answered yes to any of these questions you
        could have a static electricity problem.  Because electrostatic
        attraction can create contamination problems when processing
        non-conductive materials such as plastic, synthetic textiles and
        photo negatives, it can play a larger role than most people
        recognize in hurting a company's productivity.


           The solution to these problems is a simple, effective tool: a
        Model 224CL Static Locator Meter. The Model 224CL Static
        Locator Meter is a portable, non-contacting static meter that               MODEL         PRICE
        produces consistently accurate readings and will provide years of            224CL        $558.00
        trouble free use.



        How to use the meter.

        1) With the switch on, point the probe about 90° away from the
           charged surface (see drawing, position A).
        2) Press the button and swing the instrument to face the charged
           surface at a distance (D) of 5" (see drawing, position B).
        3) If the meter is off scale, repeat steps 1 and 2 changing the
           distance to 10".
        4) If the meter reading is on scale but low, repeat steps 1 and 2
           using a distance of 3", 2" or 1".
        5) Full scale calibration in kilovolts is numerically equal to distance
           (D) in inches, so 1" Full Scale = 1KV, 5" Full Scale = 5KV, etc.
        6) Because of possible error in estimating distance, you may wish
           to take several readings and average the results.



        CAUTION:
        DO NOT USE THIS INSTRUMENT IN THE PRESENCE OF ANY IONIZERS. TURN OFF IONIZERS WHEN TAKING READINGS.
        DO NOT CONTACT STATIC-LADEN MATERIAL WITH THE 224CL METER, AS IT MAY DAMAGE THE INSTRUMENT.

                  PLASTIC PROCESS EQUIPMENT, INC.                                            www.ppe.com
                                                                                            e-mail: sales@ppe.com
                   E 8303 CORPORATE PARK DRIVE         W  6385 MONTESSOURI STREET
                  A MACEDONIA, OHIO 44056-2300         E  LAS VEGAS, NEVADA 89113-1186  Toll Free: USA, Canada & Mexico
                   S 216-367-7000 • FAX: 216-367-7022  S  702-433-6385 • FAX: 702-433-6388  800-362-0706
                   T TOLL FREE: 800-321-0562            T  TOLL FREE: 800-258-8877         Order Fax: 800-223-8305
        90
   85   86   87   88   89   90   91   92   93   94   95